brand | KRIWAN |
Model | INT69VSY-2 |
A large number of please contact: - / Mr. Gao (can be opened VAT invoice - need to increase the tax of 17%), please call the details!
Our company is the general agent of Germany crayven (KRIWAN) Chinese area, so the product can guarantee absolute German KRIWAN original authentic, not disassemble in our products, please rest assured to buy customers and friends, we are committed to a penalty ten!
|
Application: KRIWANCorporateINT69 VSY-IIThe protection module can complete the general temperature monitoring, especially the famous switchgearINT69 VSAs well as phase sequence monitoring for screw and screw compressor.
Function introduction: If the temperature of the thermistor is exceeded, the module is closed and locked. When the supply voltage is also connectedD1Three phase power supply phase sequence monitoring. - phase sequence can also be turned off and locked.D1Allows the user to input control - rotation off. This is due to the pressure balance after the screw compressor is closed. Power off5Seconds after the self-locking can be lifted. technical data Supply voltage | AC 50/60Hz 230 + 10% 3VA | ambient temperature | -20... +60 C | Measuring circuit -Sensor type -Sensor quantity -Change-over switch -Connector | PTCThermistor basisDIN 44081/082standard 1... NineSeries input,25 <1.8K ohm Relay disconnect:>11.4K + 20% Relay on:>2.95K + 20% Orange wire.about300mm
| Phase sequence monitoring: -Operation identification -Motor voltage - L1,L2,L3Connector -About phase sequence time | L-Voltage connectionD1port AC 20... 80Hz 200... 400V Wire length approx..250mmand6.3mmConnector plug <0.5s
| Relay | AC 25OV, max.5A, 300VA = st1 ns = "urn:schemas---com:office:smarttags" ind. prefix | Service life | 1 x 106switching frequency | Shell | PA6 GF30 | Protection grade UseEN 60529standard | Add terminal cover:IP20 No terminal cover:IP00 | install | 35mmStandard guide rail installation basis,EN 50022Standard or bottom mounted directly | Terminal cover size | 87 x 40 x 58mm | weight | about210g | Work setting | Be locatedLandD1Jumper between |
menubar
temperature | Phase sequence | ConnectD1 | warning | annotation | <Trigger value | / | Inoperation | normal | Not evaluated Phase sequence | >Trigger value | / | Inoperation | error | triggerPTCerror No phase sequence | <Trigger value | Clockwise or motionless | work | normal | Normal condition | >Trigger value | Clockwise or motionless | work | error | BecausePTCError triggering | <Trigger value | Counter-clockwise direction | work | error | Phase sequence trigger | >Trigger value | Counter-clockwise direction | work | error | BecausePTCPhase sequence error triggering |
|
Product reviews can be carried out after the member login, please
click here to login